196
TECHNICAL DATA
GENERAL INFORMATION - Introduction & Specification
Flush-Mount Heating/Floor Heating Thermostat
Introduction
The design of this flush-mount thermostat’s plastic-housing
is set to enable users to either install thermostat on wall in
new-built-house.
Floor heating thermostat
FD18000 White
FD18000-A Beige
FD18000-M Black
Room heating thermostat:
FD18001 White
FD18001-A Beige
FD18001-M Black
NEW ELECTRONIC THERMOSTATS
FD18000/FD18000-A/FD18000-M
FD18001/FD18001-A/ FD18001-M
14.
Temperature sensor: 100K at 25°C
15.
Heating ON/OFF indicator: LED on front panel.
16.
Alternating temperature indication between
the setpoint and the actual sensed temperature.
(
By pressing the button on the Panel)
17.
Backlit: Color blue, 15 seconds Auto mode.
INSTALLATION
Wiring & Choosing the heating control mode
Disconnect the main before wiring
Wiring
Thermostat unit …………….........…1
Self-tapping screw 5- ¾” …...........2
Plastic anchor ø9 mm x 25 mm......2
Machine screw #3 x 20 mm .........2
Instruction sheet ……………...........1
Mounting brackets ...................... 3
Floor Sensor ………..................…4-meter#
The assisting tools may require for installation:
.
Hammer
.
Masking tape
.
Screw driver
.
Drill and Drill bit (if not installed on a junction box)
Connect the unit using the terminals located on the back taking care to
follow the wiring diagram indicated below.
Specification
1.
Thermostat operate power: 230Vac ± 10%, 50/60Hz.
2.
Display: LCD digital display.
3.
Circuitry power consumption: 7 VA
4.
Output format : Volt output.
5.
Output rating: 16(3)A / 250 Vac.
6.
Temperature indication: Celsius ( ).
7.
Temperature sampling rate: 1 minute.
8.
Working mode:
Room-Temperature control or
Floor temperature control mode is selectable to
users, by jumper-selector provided on the PCB.
9.
Temperature display range: 0 ~ 60°C
10.
Temperature control range: 5 ~ 45°C
11.
Setpoint adjusting: 0.5°C/step.
12.
Switching differential (Hysteresis):
4
selections available for choice.
13.
Prevention of losing setting in power outage:
By non-volatile EEPROM, auto resume previous
setting after power retrieved.
Two poles
isolation switch
LOAD:
Max. Rating:
16
A/250V
230
VACВ±10%, 50-60 HzГц
4
m sensor cable
Warning: Wiring work can be dangerous !
Please consult with qualified electrician or contractor.
DANGER
Electric Shock Or Fire Hazard