TECHNICAL DATA
Display on LCD to indicate respective operation modes
There are 3 operation modes:
Select the required operation mode
A.Room mode-- Room sensor controls
Display on LCD will show room-mode symbol.
(
Room sensor is positioned inside
the thermostat)
Room sensor must be enable
B.Floor mode (Floor heating) -- Floor sensor
controls
Display on LCD will show.
Room sensor must be disabled
C.Room + Floor limitation(Floor heating)
Room sensor controls on/off with
Floor sensor controls floor
temperature limitation.
Display on LCD will show
Room Sensor must be enabled
and floor-sensor must be connected
Press Reset
before starting
operation
Enable or
disable the room
temperature sensor
The unit will automatically determine the required
operation mode by detecting what temperature sensors
were connected to this unit after reset of upon the first time
use of thermostat.
FD18004 White
FD18004-M Black
FD18004-A Beige
The three operation modes provided by the unit are:
1.
Room thermostat— Room sensor controls heating
operation.
2.
Floor thermostat--Room sensor disabled, floor sensor
cable connected to the unit.
3.
Room+ Floor temperature limitation thermostat
Room sensor remains the primary control to thermostat,
Floor temperature sensor functions as floor-temperature
limitation.
E.g.
If Room sensor JUMPER is enabled, floor-sensor cable
is NOT connected; this unit will operate as a room
thermostat.
If Room sensor JUMPER is disabled, floor-sensor cable is
connected; this unit will operate as floor-sensor control
thermostat(flor thermostat).
If both room-sensor and floor-sensor cable are connected
to the unit, it will operate as a Room-temperatre-control +
Floor limitation thermostat.
(
Room+ Floor temperature limitation thermostat)
NEW MULTI-FUNCTION THERMOSTAT
FD18004/FD18004-A/ FD18004-M
Connect the floor-sensor cable to the unit from terminals #6
and #7 which are situated on the back of thermostat.
Floor Sensor
Jumper