203
air-flow, stagnant air-flow location is not suitable for installing thermostat.
(4).
Keep thermostat away from high humid ambience, high humidity is
hazardous to thermostat’s operational duration.
(5).
It’s crucial, before installing thermostat, make sure house renovation is
finished, no tacky painting/plaster is right on thermostat’s installing position.
(6).
To level thermostat prior to installation is not necessary.
(7).
Push excess cable wires back into the wall while positioning thermostat.
If there is a draft, pack the opening with non-combustible material.
(8).
Place batteries in thermostat requiring batteries, observing “+” and “-”
positions.
Content in package
FD18002/FD18003
1.
Thermostat x 1 unit
2.
Instruction sheet x 1 set
3.
Alkaline AA x 2 pieces
4.
Anchor Φ9 25 x6 mm x 2 pieces
5.
Self tapping screw M3.5 25x6.8 mm x 2 pieces
6.
Self tapping screw M3 19x5.3 mm x 2 pieces
7.
Machine screw #6-32T 3/4” x 1 pieces
8.
Machine screw #6 32T 1-1/2” x 1 pieces
Product descriptions
Wiring Guide
FD18002/FD18003 Contact Rating: 16 (3,5) A/250 V
1.
Rotary switch pointed to “RUN”.
2.
Press
to enter clock adjusting.
3.
Press or to select the accurate day of week.
4.
Press
again to enter setting the hour of day.
5.
Press or to adjust.
6.
Repeat procedure of pressing
and / to
complete setting the minute.
7.
Wait 8 seconds,the thermostat will automatically retain
Setting/ Adjusting the clock before programming the thermostat the clock time
setting and start to operate.
HOLD
Set temperature Permanent
maintained at certain
setpoint
Program setting
rotary switch
Clock setting/
adjusting
To set Lo
temperature
setpoint
To set Hi
temperature
setpoint
To reset
thermostat
For adjusting
temperature
setpoint or to
adjust clock
I
ndicates
thermostat ON/OFF status.
Battery holder
ON/OFF
Push to cut-off Relay
output (LCD display shall
show OFF)
Position switch at
adjusting
Room Temp.”
to read actual room
temperature
(
FD18002)
UP
DOWN
DANGER
READ ALL WIRE SIZING, VOLTAGE
REQUIREMENT AND SAFETY
DATA AVOID PROPERTY DAMAGE AND
PERSONAL INJURY
Electric Shock Or Fire Hazard
Do not connect
terminal 6 to main
supply, or unit will
be damaged
Connect the wires from
the terminals situated on
the back of thermostat
housing. Push excess
cable
wires back into the wall
through the square hole.
The Room sensor
to indicate
the actual
room temperature
Manual ON/OFF switch
HEATER
Floor Sensor
The floor temperature
sensor commissioning
the heating ON/OFF
to the desired setpoint.
Two pole
isolation switch
AC INPUT
Do not connect terminal
1, 2 & 6
to main supply,
or unit will be damaged
Manual ON/OFF switch
Room sensor
commissioning
the heating
ON/OFF
to the desired
setpoints
Connect the wires from
the terminals situated on
the back of thermostat
housing.
Push excess cable wires
back
into the wall through the
square hole.
HEATER
Two pole
isolation switch
AC INPUT