200
TECHNICAL DATA
Room Thermostat - Room sensor controls
Floor Thermostat - Floor sensor controls
Press both the and for 5 seconds to enter
setting mode. Follow procedure below to set/adjust
settings
Press both the and for 5 seconds to enter
setting mode. Follow procedure below to set/adjust
settings.
1.
Press or to select °C or °F
2.
Press for next adjustment, the COMFORT
default value.
3.
Press or to select the required setpoint
for COMFORT.
4.
Press again the , to choose the required
ECONOMY default value .
5.
Press or to select the required setpoint
for ECONOMY.
6.
Press for next adjustment, the
Switching Differential(Hysteresis).
7.
Press or to select the required switching
differential (5 selections).
8.
When adjustments has been completed, press again
the button and start to operate.
Reminder
In Floor Thermostat, COMFORT setpoint cannot be
set above “Hi Limit”, ECONOMY setpoint cannot be
set lower than “Lo Limit”.
1.
Press or to select °C or °F
2.
Press for next adjustment, the” Hi Limit”
default value. (Heating will shut off when temperature
reaches Hi Limit)
3.
Press or to select the required setpoint
for Hi Limit .
4.
Press again the , to choose desired “ Lo Limit”
default value. (Heating will automatic activate
temperature reaches LO Limit)
5.
Press or to select the required setpoint
for “Lo Limit”.
6.
Press for next adjustment, the COMFORT
floor temperature setpoint.
7.
Press or to choose the required COMFORT
floor temperature setpoint.
9.
Press or to choose the required ECONOMY
floor temperature setpoint.
10.
Press the to choose the required
switching differential(Hysteresis).
11.
Press or to select the required switching
differential (4 selections).
12.
When adjustments has been completed, press again
the button and start to operate.
8.
Press again the button for next adjustment, the
ECONOMY floor temperature setpoint.
Manual Temperature Setting & Internal Setting Adjustment # 1
Heating on/off indicator