201
Manual Temperature Setting & Internal Setting Adjustment # 2
Room + Floor limitation Thermostat
Room sensor & Floor sensor joint control
Press both the and for 5 seconds to enter
setting mode. Follow procedure below to set/adjust settings.
1.
Press or to select °C or °F
2.
Press for next adjustment, the COMFORT
room temperature setpoint.
3.
Press or to select the requiredtemperature
setpoint for COMFORT .
4.
Press for next adjustment, the ECONOMY
room temperature setpoint.
5.
Press or to choose the required ECONOMY
room temperature setpoint.
6.
Press again the for next adjustment, the
Hi Limit” floor temperature limitation.(Heating will
shut off when floor temperature reaches “Hi Limit”)
7.
Press or to choose the required “ floor
temperature limitation setpoint for “Hi Limit”.
8.
Press the to choose the required switching differential
(
Hysteresis).
9.
Press or to select the required switching
differential (5 selections).
10.
Once all adjustment are completed, press again
the button and start to operate.
Reminder
In Room+Floor-Limitation Thermostat, COMFORT
setpoint cannot be set above “Hi Limit”.
Manual temperature setting
Users can conveniently increase or decrease temperature
setpoint by pressing or buttons
while the thermostat is operating.
The Symbol will appear on the LCD while
thermostat is operating in Override mode.
This manual change of the temperature setpoint will
not alter Comfort or Economy settings.
Wiring
Connect the unit using the terminals situated at the back of
thermostat. Be certain to follow the wiring instruction shown.
Warning
:
Wiring work can be dangerous !
Please consult with qualified electrician
or contractor